FANUC MTConnect Machine Monitoring
FANUC controls run a huge share of the world's CNC machines, but MTConnect is not always switched on out of the box. Here are the common ways shops get FANUC machines onto MTConnect and into a monitoring dashboard.
FANUC controls sit on machines from dozens of builders — mills, lathes, and machining centers that may otherwise share nothing. That makes FANUC machines both the biggest opportunity and the most common question in CNC monitoring: how do I get their data out in a standard way?
FANUC machines usually reach MTConnect through software that reads the control over FOCAS and publishes MTConnect: either FANUC's own MTConnect Server or a third-party adapter and agent.
What is verified about FANUC and MTConnect
Reviewed against FANUC public pages on 13 Oct 2026. Status labels: Documented, Config-dependent, Needs adapter/agent, Unverified.
| Fact | Status | Detail |
|---|---|---|
| FANUC MTConnect Server (FASMTC) | Documented | PC software from FANUC America that reads the CNC over FOCAS on Ethernet and includes an adapter and a standard MTConnect agent |
| Controls listed for FANUC MTConnect Server | Documented | Series 30i/31i/32i Model A and B, and 0i Model D and F |
| Where it runs | Documented | A Windows PC at or near the machine (FANUC lists Windows 7 and 10) |
| MTConnect served directly by the control with no PC | Unverified | We found no public FANUC source confirming this for current controls; ask FANUC or your builder |
| FANUC MT-LINKi | Documented | FANUC's own data collection software; connects FANUC CNCs over FOCAS. FANUC says development has ended and points to FIELD system Basic Package |
| FEAI reads FOCAS | Not supported | FEAI reads MTConnect only. A FANUC machine needs an MTConnect agent first |
| FEAI tested on a real FANUC control | Unverified | Test your own machine on the free plan |
Path 1: FANUC MTConnect Server
FANUC America sells FANUC MTConnect Server, software that runs on a Windows PC on the shop network. It reads supported controls over FOCAS and serves standard MTConnect XML through a bundled adapter and agent.
What to check:
- The control series and model against FANUC's supported list
- That Ethernet is enabled on the control and reachable from the server PC
- Licensing and price, which FANUC does not publish on the product page
- The IP address and port the server's agent uses
Your machine builder or FANUC service can confirm what a specific control supports and what it costs.
Path 2: A third-party FOCAS-based adapter and agent
Integrators and open-source projects also build adapters that use FANUC's FOCAS library to read the control over Ethernet, then feed an MTConnect agent. The adapter and agent typically run on a small Windows or Linux PC or gateway on the shop network, and one agent can serve several FANUC machines.
This is how the open-source MTConnect ecosystem and many integrators bring FANUC machines onto MTConnect. Your monitoring software reads standard MTConnect, and never touches FOCAS directly. MTConnect vs FOCAS explains the difference.
Path 3: An existing agent from an earlier project
Many shops already have FANUC machines publishing MTConnect from a previous monitoring trial, MES project, or dealer installation. Try http://<ip>:5000/current against any agent PC on the network before buying anything. See Already Have MTConnect?
Comparing the paths
| FANUC MTConnect Server | Third-party FOCAS adapter | Existing agent | |
|---|---|---|---|
| Extra hardware | Windows PC | PC or gateway | Already there |
| Who sets it up | FANUC, builder or integrator | Integrator or in-house | Already done |
| Cost | Not published by FANUC | Adapter software and PC | None |
| Data depth | Defined by FANUC's adapter | Defined by the adapter | Varies |
| Controls covered | FANUC's published list | Depends on the adapter | Varies |
Prerequisites for any path
- Ethernet enabled on the control and connected to the shop network
- A fixed IP address for each control so the adapter or monitoring software can find it
- Network access from the agent or monitoring PC to the control
- Someone to own it — usually a builder, dealer, or integrator for setup, and someone in-house for day-to-day checks
What data to expect from FANUC MTConnect
Most setups publish the essentials for monitoring:
| Data item | Used for |
|---|---|
| Execution | Running, idle, and stopped time |
| ControllerMode | Automatic vs manual and MDI |
| Program | Which job is running |
| PartCount | Production and OEE performance |
| Conditions / alarms | Fault time and recurring alarms |
| Spindle speed, load, feed override | Cutting activity and overrides |
Exactly which items appear depends on the option or adapter. Check /probe for each machine.
Testing a FANUC machine's MTConnect feed
- Open
http://<ip>:<port>/probeon the monitoring PC and confirm the device appears. - Open
/currentand check Execution, Program, and PartCount have real values. - Run a cycle and refresh — Execution should go ACTIVE and PartCount should increase if counting is enabled.
How to Test an MTConnect Connection covers every failure mode.
Questions to ask your builder or integrator
- Which FANUC control series and software does this machine have?
- Is FANUC MTConnect Server or another MTConnect adapter available for this control, and what does it cost?
- Is Ethernet enabled on the control, and which IP address does it use?
- If you supply an adapter, which data items does it publish, and where does the agent run?
- Who supports the adapter PC when it needs updates or a restart?
Common FANUC MTConnect problems
- Ethernet not enabled on the control, or plugged into a different network.
- Adapter PC turned off or asleep, so every machine it serves goes offline at once.
- Part count not incrementing because the program does not trigger the counter.
- Wrong path on multi-path lathes, so running time looks too low.
Monitoring FANUC machines with FEAI
Once a FANUC machine publishes MTConnect, FEAI Machine Monitor reads it like any other: live status, timelines, utilization, OEE, downtime, and shift reports. Mixed fleets show FANUC machines side by side with Haas, Mazak, and Okuma machines.
FEAI is a read-only MTConnect client. It does not use FOCAS directly, does not install adapters, and does not configure controls.
Sources (reviewed 13 Oct 2026)
- FANUC MTConnect Server: https://www.fanucamerica.com/products/software/cnc/mt-connect-server
- FANUC MT-LINKi: https://www.fanucamerica.com/products/software/cnc/mt-link-i
- MTConnect Institute: https://www.mtconnect.org/
FANUC machine publishing MTConnect? Start Free — Monitor 2 Machines. Still deciding how to connect it? Compare routes in MTConnect vs FOCAS.
FAQ
Do FANUC controls support MTConnect?
FANUC America sells FANUC MTConnect Server, PC software that reads supported controls over FOCAS and publishes MTConnect. It lists Series 30i/31i/32i Model A and B and 0i Model D and F. Third-party FOCAS-based adapters are another route. Availability depends on the control series, software and options.
Can I monitor FANUC machines without FOCAS?
Usually FOCAS is still involved underneath. FANUC MTConnect Server and most third-party adapters read the control over FOCAS and publish MTConnect, and your monitoring software reads standard MTConnect.
What do I need to monitor a FANUC machine with FEAI?
An accessible MTConnect Agent or compatible endpoint for that machine, reachable from the Windows PC running FEAI. FEAI does not use FOCAS directly.
Do FANUC machines need Ethernet for monitoring?
Yes in practice. FANUC MTConnect Server and third-party FOCAS-based adapters communicate over the control's Ethernet connection, which must be enabled and on the shop network.
Can FANUC and non-FANUC machines be monitored together?
Yes. Once each machine publishes MTConnect, a single client shows them side by side.
Who sets up a FANUC MTConnect adapter?
Usually your machine builder, dealer, or an integrator. FEAI reads the resulting agent and does not configure controls.